Libero by ELPRO
Transportation > Cold Chain Monitoring
LIBERO Ti1
Compact temperature data logger with an integrated NTC sensor
LIBERO Ti1 can be used once or several times (as a 1 or 2 year logger).
Versatile application: for mappings as a back-up solution or simply for recording temperature.
- PDF Logger with internal NTC probe
- Lifetime: 400 days, multiple use
- Measuring range: -35 °C..+70 °C /
- Memory capacity: 16'000 values
- Connection: USB
- Validation certificate based on ELPRO Lot Acceptance Test
Logger/module type:PDF-Logger
Probe type: Datalogger with NTC-Probe, internal
Typical application area: Freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 400 Days
Dimensions: 95 x 40 x 12 mm /38 g
Material: ABS plastic material
Protection class: IP 54
LIBERO Ti1-S
PDF Logger with internal NTC probe
Lifetime: 100 days, single use
Measuring range: -35 °C..+70 °C
Memory capacity: 16'000 values
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Single Use
Alarm: 6 alarm levels
Life time: 100 Days
Dimensions: 95 x 40 x 12 mm /38 g
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Ti1-L
- PDF Logger with internal NTC probe
- Lifetime: 2 years, multiple use
- Measuring range: -35°C .. 70°C
- Memory capacity: 16'000 values
- Connection: USB
- Validation certificate based on ELPRO Lot Acceptance Test
Probe type: Datalogger with NTC-Probe, internal
Typical application area: Freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Dimensions: 102 x 40 x 19 mm / 45 g
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Te1-N
Datalogger outside - measuring point inside
Are you looking for a simple monitoring solution with an external NTC sensor, for example, for a room or a box?
LIBERO Te1-N (-90 °C..+ 85 °C) can be used once or several times (as 1 or 2 year logger) and independent of internet, network or power grid
- PDF Logger for external NTC probe
- Lifetime: 2 years, multiple use
- Measuring range: -90 °C..+85 °C
- Memory capacity: 16'000 values
- With validation certificate,
- external NTC probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -90 °C..+85 °C
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C] / ±1.8 °C [-90.1 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Memory capacity: 16'000 measurement values per logger
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
LIBERO Te1-U
Logger with internal NTC probe
Lifetime: 100 days, single use
Measuring range: -90°C ..+85 °C
Memory capacity: 16'000 values
Connection: USB With validation certificate
External NTC probe not included
Probe type: Datalogger with NTC-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room, transportation box, transport, ultra deep freezer, warehouse, incubator
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+85.0 °C] / ±1.8 °C [-85.0 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Te1-NY
- PDF Logger for external NTC probe
- Lifetime: 400 days, multiple use
- Measuring range: -90 °C..+85 °C
- Memory capacity: 16'000 values
- Connection: USB
- With validation certificate,
- External NTC probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -90 °C..+85 °C
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C] / ±1.8 °C [-90.1 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Te1-P
Datalogger outside - measuring point inside !
Are you looking for a simple monitoring solution with an external Pt100 sensor, e.g. for a room or a box?
LIBERO Te1-P (-200 °C..+200 °C) can be used once or multiple times as a 1 or 2 year logger, independent of internet, network or power grid.
- PDF Logger for external Pt100 probe
- Lifetime: 2 years, multiple use
- Measuring range: -200 °C..+200 °C
- Memory capacity: 16'000 values
- Connection: USB
- Validation certificate,
- External Pt100 probe not included
Logger/module type: PDF-Logger
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
LIBERO Te1-PS
- PDF Logger for external Pt100 probe
- Lifetime: 100 days, single use
- Measuring range: -200 °C..+200 °C
- Memory capacity: 16'000 values
- Connection: USB
- With validation certificate
- External Pt100 probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room, transportation box
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 100 Days
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
LIBERO Te1-PY
- PDF Logger for external Pt100 probe
- Lifetime: 400 days, multiple use
- Measuring range: -200 °C..+200 °C
- Memory capacity: 16'000 values
- Connection: USB
- Validation certificate
- External Pt100 probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 400 Days
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
PRO_NTC_PLA20D5_PLA3_USB
- LIBERO NTC temperature probe
- -50°..+85°C NTC
- with USB connector for LIBERO Te1-N
- P=5x20mm, round cable, waterproof,
- L=3m
PRO_NTC_P20D5_RUB0.8_USB
- NTC temperature probe with USB-connector
- Measuring range: -90 °C..+85 °C
- Rubber, P=5x20mm, L=80cm, waterproof
- Single use with LIBERO Te1-U/Te1-N for dry ice application
PRO_PT100_ST350D3_SIL5
- Pt100 4-wire ML-temperature probe, Ø 3 L= 350 mm,
- Temperature range -200
°C..+500 °C,
- Class A -30 °C..+300 °C otherwise class B,
- bendable,
- silicon cable L=5m,
- without connector
PRO_PT100_ST350D3_SIL5
- Pt100 4-wire ML-temperature probe, Ø 3 L= 350 mm,
- Temperature range -200
°C..+500 °C,
- class A -30 °C..+300 °C otherwise class B,
- bendable,
- silicon cable L=5m,
- without connector
- for dry application only
LIBERO THi1-S
PDF Logger for temperature & relative humidity
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Life-time: 100 days, single use, Non-replaceable battery
Measuring range: T: -25°C .. 70°C,
rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate and ELPRO label
Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] /±3% rF [65.1% rF..80% rF] /± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Alarm: Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
SINGLE USE
Measurement interval : 1 to 60 minutes, user programmable
LIBERO THi1-Y
PDF Logger for temperature & relative humidity
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Lifetime: 400 days, multiple use, Non-replaceable battery
Measuring range: T: -25°C .. 70°C,
rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] / ±3% rF [65.1% rF..80% rF] /± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Alarm: Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
Measurement interval : 2 to 60 minutes, user programmable
LIBERO THi1
PDF Logger for temperature & relative humidity Typical application area: Freezer, refrigerator, room, climate room, transportation box
Lifetime: 2 years, MULTI USE, Non-replaceable battery
Measuring range: T: -25°C .. 70°C,
rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] / ±3% rF [65.1% rF..80% rF] /± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
Measurement interval : 5 to 60 minutes
BRA_LIBERO Tx
Simple bracket for LIBERO Tx
ABS plastic, black, with 2 adhesive tapes
BRA_LIBERO Te1-x
LIBERO bracket stainless version for connection of external probes with terminals
- for - Pt100 (3-wire) for LIBERO Te1-Px
- or - NTC (2-wire) for LIBERO Te1-Nx
Typical application area:
Liquid nitrogen vessel,dry ice, freezer, refrigerator, room, climate room, transportation box, transport, ultra deep freezer, warehouse, incubator