Libero by ELPRO - Senze-Instruments Benelux

Senze-Instruments BENELUX
Go to content
Process & Quality Control

Libero by ELPRO

Transportation > Cold Chain Monitoring
LIBERO Ti1
Compact temperature data logger with an integrated NTC sensor
LIBERO Ti1 can be used once or several times (as a 1 or 2 year logger).     
Versatile application: for mappings as a back-up solution or simply for recording temperature.

  • PDF Logger with internal NTC probe
  • Lifetime: 400 days, multiple use
  • Measuring range: -35 °C..+70 °C /
  • Memory capacity: 16'000 values
  • Connection: USB
  • Validation certificate based on ELPRO Lot Acceptance Test      
Logger/module type:PDF-Logger
Probe type: Datalogger with NTC-Probe, internal
Typical application area: Freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 400 Days
Dimensions: 95 x 40 x 12 mm   /38 g  
Material: ABS plastic material
Protection class: IP 54

LIBERO Ti1-S

PDF Logger with internal NTC probe
Lifetime: 100 days, single use
Measuring range: -35 °C..+70 °C  
Memory capacity: 16'000 values
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Single Use
Alarm: 6 alarm levels
Life time: 100 Days
Dimensions: 95 x 40 x 12 mm /38 g
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate

LIBERO Ti1-L

  • PDF Logger with internal NTC probe
  • Lifetime: 2 years, multiple use
  • Measuring range: -35°C .. 70°C  
  • Memory capacity: 16'000 values
  • Connection: USB
  • Validation certificate based on ELPRO Lot Acceptance Test
Probe type: Datalogger with NTC-Probe, internal
Typical application area: Freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Dimensions: 102 x 40 x 19 mm / 45 g
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Te1-N
Datalogger outside - measuring point inside
Are you looking for a simple monitoring solution with an external NTC        sensor, for example, for a room or a box?     
LIBERO Te1-N (-90 °C..+ 85 °C) can be used once or several times (as 1        or 2 year logger) and independent of internet, network or power grid     

  • PDF Logger for external NTC probe
  • Lifetime: 2 years, multiple use
  • Measuring range: -90 °C..+85 °C
  • Memory capacity: 16'000 values
  • With validation certificate,
  • external NTC probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -90 °C..+85 °C
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C] / ±1.8 °C [-90.1 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Memory capacity: 16'000 measurement values per logger
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54

LIBERO Te1-U  

Logger with internal NTC probe
Lifetime: 100 days, single use
Measuring range: -90°C ..+85 °C  
Memory capacity: 16'000 values
Connection: USB With validation certificate
External NTC probe not included
Probe type: Datalogger with NTC-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room, transportation box, transport, ultra deep freezer, warehouse, incubator
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+85.0 °C] / ±1.8 °C [-85.0 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Dimensions: 102 x 40 x 19 mm / 45 g  without probe
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
LIBERO Te1-NY

  • PDF Logger for external NTC probe
  • Lifetime: 400 days, multiple use
  • Measuring range: -90 °C..+85 °C  
  • Memory capacity: 16'000 values
  • Connection: USB
  • With validation certificate,
  • External NTC probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -90 °C..+85 °C
Measurement accuracy temperature: ±0.2 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-35.0 °C..-10.1 °C; +25.1 °C..+70.0 °C] / ±1.8 °C [-90.1 °C..-35.1 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
Certificates: Validation certificate
           
LIBERO Te1-P
Datalogger outside - measuring point inside !
Are you looking for a simple monitoring solution with an external Pt100        sensor, e.g. for a room or a box?     
LIBERO Te1-P (-200 °C..+200 °C) can be used once or multiple times as a        1 or 2 year logger, independent of internet, network or power grid.     

  • PDF Logger for external Pt100 probe
  • Lifetime: 2 years, multiple use
  • Measuring range: -200 °C..+200 °C  
  • Memory capacity: 16'000 values
  • Connection: USB
  • Validation certificate,
  • External Pt100 probe not included
                   
Logger/module type: PDF-Logger
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 2 Years
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
 

LIBERO Te1-PS

  • PDF Logger for external Pt100 probe
  • Lifetime: 100 days, single use
  • Measuring range: -200 °C..+200 °C  
  • Memory capacity: 16'000 values
  • Connection: USB
  • With validation certificate
  • External Pt100 probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room, transportation box
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 100 Days
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
LIBERO Te1-PY

  • PDF Logger for external Pt100 probe
  • Lifetime: 400 days, multiple use
  • Measuring range: -200 °C..+200 °C
  • Memory capacity: 16'000 values
  • Connection: USB
  • Validation certificate
  • External Pt100 probe not included
Probe type: Datalogger with Pt100-Probe, external
Typical application area: Liquid nitrogen vessel, dry ice, freezer, refrigerator, room, climate room
Measurement parameters: Temperature
Measurement range temperature: -200 °C..+200 °C
Measurement accuracy temperature: ±0.3 °C [-10.0 °C..+25.0 °C] / ±0.5 °C [-200.0 °C..-10.1 °C; +25.1 °C..+200.0 °C]
Usage: Multiple Use
Alarm: 6 alarm levels
Life time: 400 Days
Dimensions: 102 x 40 x 19 mm / 45 g without probe
Material: ABS plastic material
Protection class: IP 54
PRO_NTC_PLA20D5_PLA3_USB

  • LIBERO NTC temperature probe
  • -50°..+85°C NTC
  • with USB connector for LIBERO Te1-N
  • P=5x20mm, round cable, waterproof,
  • L=3m
PRO_NTC_P20D5_RUB0.8_USB

  • NTC temperature probe with USB-connector
  • Measuring range: -90 °C..+85 °C
  • Rubber, P=5x20mm, L=80cm, waterproof
  • Single use with LIBERO Te1-U/Te1-N for dry ice application  
PRO_PT100_ST350D3_SIL5

  • Pt100 4-wire ML-temperature probe, Ø 3 L= 350 mm,
  • Temperature range -200 °C..+500 °C,
  • Class A -30 °C..+300 °C otherwise class B,
  • bendable,
  • silicon cable L=5m,
  • without connector
PRO_PT100_ST350D3_SIL5

  • Pt100 4-wire ML-temperature probe, Ø 3 L= 350 mm,
  • Temperature range -200 °C..+500 °C,
  • class A -30 °C..+300 °C otherwise class B,
  • bendable,
  • silicon cable L=5m,
  • without connector
  • for dry application only
LIBERO THi1-S
PDF Logger for temperature & relative humidity
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Life-time: 100 days, single use, Non-replaceable battery
Measuring range:  T: -25°C .. 70°C,
                                         rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate and ELPRO label

Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /
±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /
±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] /
±3% rF [65.1% rF..80% rF] /
± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Alarm: Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
SINGLE USE
Measurement interval : 1 to 60 minutes, user programmable
LIBERO THi1-Y
PDF Logger for temperature & relative humidity
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Lifetime: 400 days, multiple use, Non-replaceable battery
Measuring range: T: -25°C .. 70°C,
                                        rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /
±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /
±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] / ±3% rF [65.1% rF..80% rF] /
± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Alarm:  Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
Measurement interval : 2 to 60 minutes, user programmable
LIBERO THi1
PDF Logger for temperature & relative humidity
Typical application area: Freezer, refrigerator, room, climate room, transportation box
Lifetime: 2 years, MULTI USE, Non-replaceable battery  
Measuring range: T: -25°C .. 70°C,
                                        rH 0..100% non-condensing
Memory capacity: 8'000 values per channel
Probe type: NTC-Probes, internal
Connection: USB
Validation certificate based on ELPRO Lot Acceptance Test
Measurement accuracy temperature:
±0.5 °C [+10.0 °C..+40.0 °C] /
±0.8 °C [-10.0 °C..+9.9 °C; +40.1 °C..+55.0 °C] /
±1.2 °C [+55.1 °C..+70.0 °C; -25.0 °C..-9.9 °C]
Measurement accuracy humidity:
±2% rF [10.1% rF..65% rF] / ±3% rF [65.1% rF..80% rF] /
± 4% rF [0% rF..10% rF; 80.1% rF..100% rF]
Upper and lower alarm limits for temperature and humidity
Dimensions: 102 x 40 x 19 mm
Weight : 45 g
Material: ABS plastic material
Measurement interval : 5 to 60 minutes


BRA_LIBERO Tx

Simple bracket for LIBERO Tx ABS plastic, black, with 2 adhesive tapes
BRA_LIBERO Te1-x

LIBERO bracket stainless version for connection of external probes with terminals
  • for  - Pt100 (3-wire) for LIBERO Te1-Px
  • or - NTC (2-wire) for LIBERO Te1-Nx




Typical application area:

Liquid nitrogen vessel,dry ice, freezer, refrigerator, room, climate room, transportation box, transport, ultra deep freezer, warehouse, incubator
Back to content