Real Time Monitoring Multi-Use - Senze-Instruments Benelux

Senze-Instruments BENELUX
Go to content
Process & Quality Control

Real Time Monitoring Multi-Use

Transportation > Cold Chain Monitoring
B91(2G) Real-time Temperature Positioning Monitor (Multi use + Rechargeable)

Temperature, Light, Location
  • Global real-time temperature monitor
  • Data is stored in the cloud for traceability; USB port for backup PDF data download
  • Full cold chain visibility(Location, Temperature, Light, Route) via Frigga cloud
  • Improve transportation efficiency and reduce products loss with real-time monitoring
  • 24/7 data control & analysis, manage quality and control of your products in-transit. Real time alert via SMS, Email and APP
  • Support weak light detection, protect the safety of your goods effectively

Ref : 346-B91(2G)
SPECIFICATIONS
Configure                           Parameters
Usage Type                        Multi use(Reusable)+Rechargeable
Monitor Information   Probe Temperature, Light , Location, Track routes.
Temperature Sensor    Texas Instruments (TI) Brand Digital Sensor
Temperature Measurement Range    -40°C ~ 80°C
Temperature Accuracy Range   ±0.5°C (-20°C ~ +40°C); ±1°C for other range
Resolution                             0.1°C
Light Sensor Range          0~1700 Lux,detect whether doors or cartons open
Memory Capacity             Max 28800 readings
Location Type                       LBS Base Station Positioning
Cellular                                     2G network.
SIM Card                                   Internal Embedded (Global Data Roaming)
Shelf Time                                 12 Months
Use Time                                     120 days use time for 1 charge with 120 reporting interval
Data Logging Interval          10 Min. (settable via platform)
Data Reporting Interval     10 Min. (10/20/30/60/120 Min settable via platform)
Environmental Rating          IP64
Cold Chain PDF Report       Get PDF report via USB2.0/ Frigga cloud platform/Frigga Track(Mobile App)
Dimensions/Weight               102 x 59 x 19 mm / 240 grams
Certifications                               FCC,CE,RTCA/DO-160G,UN38.3,ROHS,WEEE
Storage temperature range  -10°C ~ +55°C


T71(4G) Real-time Temperature Positioning Monitor (Multi use + Rechargeable)

Temperature, Shock, Location
  • New generation of global real-time temperature monitor
  • Data is stored in the cloud for traceability; USB port for backup PDF data download
  • Full cold chain visibility(Location, Temperature, Shock,  Route) via Frigga cloud
  • Improve transportation efficiency and reduce products loss with real-time monitoring
  • 24/7 data control & analysis, manage quality and control of your products in-transit. Real time alert via SMS, Email and APP
  • Support shock detection, protect the safety of your goods effectively

Ref : 346-T71(4G)
SPECIFICATIONS
Configure                           Parameters
Usage Type                        Multi use(Reusable)+Rechargeable
Monitor Information   Probe Temperature, Shock, Location, Track routes
Temperature Sensor   Texas Instruments (TI) Brand Digital Sensor
Temperature Measurement Range -40°C ~ 80°C
Temperature Accuracy Range  ±0.5°C (-20°C ~ +40°C);
                                                                    ±1°C for other range
Resolution                              0.1°C
Memory Capacity              Max 50000 readings
Location Type                        LBS Base Station Positioning
Cellular                                      Global LTE 4G/5G, fallback 2G network.
SIM Card                                    Internal Embedded (Global Data Roaming)
Shelf Time                                 12 Months
Use Time                                    120 days use time for 1 charge with 120 reporting interval
Data Logging Interval         10 Min. (1/2/5/10 Min settable via platform)
Data Reporting Interval     10 Min. (10/20/30/60/120 Min settable via platform)
Environmental Rating          IP64
Cold Chain PDF Report       Get PDF report via USB2.0/ Frigga cloud platform/Frigga Track(Mobile App)
Dimensions/Weight              103 x 65.6 x 18.5 mm/ 250 grams
Certifications                             FCC,CE,RTCA/DO-160G,UN38.3,ROHS,WEEE
Storage temperature range  -10°C ~ +55°C

Ref : 346-T71
T70(4G) Real-time Temperature and Humidity Positioning Monitor (Multi use + Rechargeable)

  • Temperature,Humidity, Shock, Location
  • New generation of global real-time temperature monitor
  • Data is stored in the cloud for traceability; USB port for backup PDF data download
  • Full cold chain visibility(Location, Temperature, Humidity, Shock, Route) via Frigga cloud
  • Improve transportation efficiency and reduce products loss with real-time monitoring
  • 24/7 data control & analysis, manage quality and control of your products in-transit. Real time alert via SMS, Email and APP
  • Support shock detection, protect the safety of your goods effectively

Ref : 346-T70(4G)
SPECIFICATIONS
Configure                                           Parameters
Usage Type                                       Multi use(Reusable)+Rechargeable
Monitor Information                   Temperature, Humidity, Shock, Location, Track routes
Temperature Sensor                     Internal Texas Instruments (TI) Brand Digital Sensor
Temperature Measurement Range    -30°C ~ 70°C
Temperature Accuracy Range     ±0.5°C (-20°C ~ +40°C); ±1°C for other range
Humidity Measurement Range   5%~95%RH
Humidity Accuracy Range              ±3%(20%~80%RH); ±5% for other range
Resolution(Temperature/Humidity)      0.1°C / 1%RH
Memory Capacity                                 Max 50000 readings
Location Type                                           LBS Base Station Positioning
Cellular                                                         Global LTE 4G/5G, fallback 2G network.
SIM Card                                                      Internal Embedded (Global Data Roaming)
Shelf Time                                                   12 Months
Use Time                                                       120 days use time for 1 charge with 120 reporting interval
Data Logging Interval                            10 Min. (1/2/5/10 Min settable via platform)
Data Reporting Interval                        10 Min. (10/20/30/60/120 Min settable via platform)
Environmental Rating                              IP64
Cold Chain PDF Report                           Get PDF report via USB2.0/ Frigga cloud platform/Frigga Track(Mobile App)
Dimensions/Weight                                   103 x 65.6 x 18.5 mm / 160 grams
Certifications                                                  FCC,CE,RTCA/DO-160G,UN38.3,ROHS,WEEE
Storage temperature range                     -10°C ~ +55°C

Ref 346-T70(4G)
V57(4G) Real-time Temperature and Humidity Positioning Monitor (Multi use + Rechargeable)

Temperature,Humidity, Weak Light,Shock, Location
  • New generation of global real-time temperature monitor
  • Data is stored in the cloud for traceability; USB port for backup PDF data download
  • Full cold chain visibility(Location, Temperature, Humidity, Light, shock, route) via Frigga cloud
  • Improve transportation efficiency and reduce products loss with real-time monitoring
  • 24/7 data control & analysis, manage quality and control of your products in-transit. Real time alert via SMS, Email and APP
  • Support weak light detection, protect the safety of your goods effectively

Ref : 346-V57(4G)
SPECIFICATIONS
Configure                                                                   Parameters
Usage Type                                                                Multi use(Reusable)+Rechargeable
Monitor Information                                           Temperature, Humidity, Light , Shock, Location, Track routes
Temperature Sensor                                             Internal Texas Instruments (TI) Brand Digital Sensor
Temperature Measurement Range            -30°C ~ 70°C  
Temperature Accuracy Range                        ±0.5°C (-20°C ~ +40°C); ±1°C for other range
Humidity Measurement Range                       5%~95%RH
Humidity Accuracy Range                                  ±3%(20%~80%RH); ±5% for other range
Resolution(Temperature/Humidity)             0.1°C / 1%RH
Light Sensor Range                                                  0~52,000 Lux, detect whether doors or cartons open
Memory Capacity                                                      Max 28800 readings
Location Type                                                              LBS Base Station Positioning
Cellular                                                                           Global LTE 4G/5G, fallback 2G network.
SIM Card                                                                         Internal Embedded (Global Data Roaming)
Shelf Time                                                                      12 Months
Use Time                                                                        120 days use time for 1 charge with 120 reporting interval
Data Logging Interval                                             10 Min. (settable via platform)
Data Reporting Interval                                         10 Min. (10/20/30/60/120 Min settable via platform)
Environmental Rating                                              IP64
Cold Chain PDF Report                                          Get PDF report via USB2.0/ Frigga cloud platform/Frigga Track(Mobile App)
Dimensions/Weight                                                 103 x 61.3 x 23 mm / 140 grams
Certifications                                                                 FCC,CE,RTCA/DO-160G,UN38.3,ROHS,WEEE
Storage temperature range                                  -10°C ~ +55°C
            
Ref 346-V57-4G
Back to content